HLHB-12 Environmental Gas Insulated Ring Main Unit

HLHB-12 is an environmental gas insulated ring main unit designed for medium-voltage power distribution systems up to 12 kV. It adopts environmentally friendly gas insulation technology and a fully sealed structure to ensure reliable insulation performance and stable operation under various environmental conditions. With a compact design, integrated switching and protection functions, and minimal maintenance requirements, HLHB-12 provides a safe, efficient, and flexible solution for urban and industrial distribution networks.

Share to:

Overview

HLHB-12 environmental gas insulated Ring Main Unit is a complete set of power distribution device of 12KV, three-phase AC 50Hz, single bus and single bus segment system.
The product has the characteristics of simple structure, flexible operation, reliable interlocking, convenient installation and so on, and different users can provide satisfactory technical solutions for different applications. The adoption of sensing technology, automatic control technology and information technology, coupled with advanced technical performance and simple and flexible assembly scheme, can meet the changing needs of the market, and apply to the intelligent requirements of the power grid.

The RMU is suitable for industrial and civil cable ring network and distribution network terminal engineering. As the acceptance and distribution of electric energy, it is especially suitable for urban residential area power distribution, small secondary substation, opening and closing office, cable branch box, box type substation, industrial and mining enterprises, shopping malls, airports, subways, wind power generation, hospitals, stadiums, railways, tunnels and other places.

Features

• Low-carbon and environmentally-friendly
• Strong weather resistance, and a wide range of application
• Less maintenance
• Good insulation performance, safe and reliable operation
• Intelligentize

Service Conditions

Ambient air temperature: -40°C – +50°C
Humidity: Maximum average relative value, daily ≤95%, monthly ≤90%
Altitude: ≤4000 M
Seismic resistance: 8 degrees
Use under special conditions can be negotiated

Model

Dimensions Of The Switchgear

Cabinet size (W×D×H)Circuit breaker cabinetCable connection cabinetPT cabinet
Top expansion420×850×1950420×850×1950600×850×1950
Side expansion420×850×2000420×850×2000600×850×1950

Technical Parameter

The main technical parameters of the Environmental Gas Insulated RMU

ItemUnitParameter
Rated voltagekV12
Rated currentA630
Arc extinguishing methodVacuum switch tube
Insulation methodPure air or nitrogen
Rated short circuit breaking currentkV20
Rated short circuit breaking timesTimes30
Rated short-circuit closing current (peak)kV50
Rated short-time withstand current 3s (rms)kA20 (Main circuit), 17, 4 (Earthing circuit)
Rated peak withstand currentkA50 (Main circuit), 43, 5 (Earthing circuit)
Power frequency withstand voltage (1min)kV42 (Phase to earth, phase to phase), 48 (breaking)
Lightning impulse withstand voltagekV75 (Phase to earth, phase to phase), 85 (breaking)
Partial dischargePC≤20
Rated sequence of operations of vcbsO-0.3S-CO-180S-CO
Withstands internal arc faultsKA\S20/0.5
Mechanical lifeTimes10000 (VCB) 3000 (Isolating switch, Earthing switch)
Main circuit resistance of each phaseμΩ120
Earthing switch rated short-circuit making current (peak value)KA43,5
Earthing switch closing timesTimes2
Degree of protectionMPaIP67 (Gas box), IP4X (body case)
Rated gas pressure (gauge pressure)MPa0.02
Minimum operating gas pressure0/00
Rated annual leakage rateppm0.01
Moisture content in air boxKV≤150
Auxiliary circuit power frequency withstand voltage (1min)2

Main Technical Parameter Of Circuit Breaker

ItemUnitParameter
Rated voltagekV12
Rated currentA630
Rated short-circuit breaking currentkA20
Rated short-circuit closing current (peak)kA50
Rated short-time withstand current 3s (rms)kA20
Rated peak withstand currentkA50
Rated sequence of operationsO-0.3s-C.O.-180s-C.O.
Power frequency withstand voltage (1min)kV42 (Phase to earth, phase to phase), 48 (breaking)
Lightning impulse withstand voltage (peak)kV75 (Phase to earth, phase to phase), 85 (breaking)
Partial dischargePC≤5
Mechanical lifeTimes10000
Main loop resistance per phaseμΩ≤110
Contact spacingmm9±1
Contact pressure over-travelmm3±0,5
Contact final pressureN1800±100N
Three-phase opening (different phases)ms≤1
Contact closure bounce timems≤2
Closing timems≤70
Opening timems≤60
Average opening speedm/s1.1±0.2
Average closing speedm/s0.8±0.2
Rated number of short-circuit current breaksTimes30

The Main Technical Parameters Of The Main Circuit (Disconnector) Of The Combined Grounding Switch On The Busbar Side

ItemUnitParameter
Rated voltagekV12
Rated currentA630
Rated short-time current 3s (rms)kA20
Rated peak withstand currentkA50
Power frequency withstand voltage (1min)kV42 (Phase to earth, phase to phase), 48 (breaking)
Lightning impulse withstand voltage (peak)kV75 (Phase to earth, phase to phase), 85 (breaking)
Three-phase opening (different phases)mm≤2
Mechanical lifeTimes3000
Total resistance of each phase main circuitμΩ≤60
Contact pressureN160±20
Closing forceNm≤100
Moving and static contact distancemm≥125

The Main Technical Parameters Of The Grounding Circuit (Grounding Switch) Of The Combined Grounding Switch On The Busbar Side

ItemUnitParameter
Rated voltagekV12
Rated currentA630
Rated short-time withstand current 2s (rms)kA17, 4
Rated peak withstand currentkA43.5
Power frequency withstand voltage (1min)kV42 (Phase to earth, phase to phase), 48 (breaking)
Lightning impulse withstand voltage (peak)kV75 (Phase to earth, phase to phase), 85 (breaking)
Three-phase opening (different phases)mm≤1
Mechanical lifeTimes3000
Total resistance of each phase main circuitμΩ≤60
Contact pressureN160±20
Closing forcenm≤100
Rated short-circuit closing currentKA43, 5
Closing timesTimes2
Moving and static contact distancemm≥125

Main Technical Parameters Of Spring Energy Storage Operating Mechanism

ItemUnitParameter
Auxiliary circuit rated voltageVDC48, DC110, AC220, DC220
Auxiliary circuit power frequency withstand voltage (1min)kV2
Opening and closing coil voltageVDC48, DC110, AC220, DC220
Opening coil currentA2
Closing coil currentA2
Rated voltage energy storage times≤20
Auxiliary switch rated voltageVDC48, DC110, AC220, DC220
Auxiliary switch rated currentA10
Pairs of the auxiliary switch contact80 8C