Overview
XGN66A-12 Series switchgear panel is a MV air-insulated switchgear (AIS) for primary distribution, with vacuum circuit-breaker has been designed for the various operating requirements in public and industrial medium-voltage distribution systems. This panel applies to 3.6 ~ 12kV 3 phase AC 50Hz / 60Hz network for receiving and distributing power energy and also for control, monitor and protection. It can be arranged for single bus, single-bus sectionalizing system. It accords to IEC62271-200 <<AC Metal Enclosed Switchgear and Control Equipment above 1kv and below 52kv>>, IEC694<<Standard Common Clause for HV Switchgear and Control Equipment>>, GB3906<<3 ~ 35KV AC Metal Enclosed Switchgear>>, DL404<<Order Specification for Indoor AC HV Switchgear>>, DIN.VDE0670<<AC Switchgear at Rated Voltage over 1kv>> and so on. It has perfect and reliable prevention function against false-operation.
Operating Conditions
Normal operating conditions, according to the IEC International Standards listed below, for indoor switchgear.
Ambient air temperature
• Less than or equal to 40℃
• Less than or equal to 35℃ on average over 24 hours
• Greater than or equal to -5℃ (-25℃ on request)
Altitude
• Less than or equal to 1000 m;
• Above 1000 m, a derating coefficient is applied (please consult us)
Atmosphere
• No dust, smoke, or corrosive, or inflammable gas and vapor, or salt
• Earthquake intensity:Magnitude 8
Humidity
• Average relative humidity over a 24 hour period ≤ 95%
• Average relative humidity over a 1 month period ≤ 90%
• Average vapor pressure over a 24 hour period ≤ 2.2 kPa
• Average vapor pressure over a 1 month period ≤ 1.8 kPa
Feature
• This panel is fixed type.
• Reliable “anti-5” mechanical latch, convenient and safe maintenance.
• Both VCB of ZN63□-12 / HLVP-12 (VS1-12) developed by our company and VD4, VB2 AND 3AH manufactured by other companies around the world can be matched with the switchgear.
Technical characteristics
| Item | Unit | Data |
|---|---|---|
| Rated voltage | KV | 3.6, 7.2, 12 |
| Rated insulation level | KV | |
| 1min.P.F. withstand voltage (phases to ground/gaps) | KV | 42/48 |
| Lightning impulse withstand voltage (phases to ground/gaps) | KV | 75/85 |
| Rated frequency | Hz | 50/60 |
| Rated current | A | 630,1250,1600,2000,2500,3150,4000,5000 |
| Rated short-time withstand current(4s) | KA | 16,20,25,31.5,40,50 |
| Rated peak withstand current※ | KA | 40,50,63,80,100,125 |
| Protection class | IP2X | |
| Outline dimension (width×depth×height) | mm | 900(1100)x1000x2300 |
| weight | kg | 800-1100 |
Model